為了保證沼氣使用的,我們要對沼氣進行脫硫和脫水等一系列的提純操作,下面小編就給大家愛介紹一下沼氣汽水分離器在運行中應注意的一些問題?
In order to ensure the safety of the use of biogas, we need to carry out a series of purification operations such as desulfurization and dehydration of biogas. The following edition will introduce some problems that should be paid attention to in the operation of the biogas vapor-water separator.
1、檢查安裝位置和流向,確保箭頭安裝在閥體上。
1. Check the installation position and flow direction to ensure that arrows are installed on the valve body.
2、在水平管道上安裝,排水口垂直向下,排水口與自動排水裝置連接(僅適用于壓力小于1.6MPa)。
2. Install on horizontal pipeline, drainage outlet is vertical downward, drainage outlet is connected with automatic drainage device (only applicable to pressure less than 1.6 MPa).
3、設有旁通閥和進出口截止閥,維護不會影響生產(chǎn)。
3. With bypass valve and import and export globe valve, maintenance will not affect production.
4、新管道投產(chǎn)或長輸管道啟動時,請先用隔離設備清洗管道,然后啟動設備。
4. When the new pipeline is put into operation or the long distance pipeline is started, please clean the pipeline with isolation equipment first, and then start the equipment.
5、當過濾壓力明顯升高時,請及時更換過濾元件,防止空壓機負荷增加。
5. When the filtration pressure is obviously increased, please replace the filter elements in time to prevent the increase of the load of the air compressor.
6、更換過濾器元件時,請連接旁通閥并關閉進出閥。排空槽中的壓縮空氣被除去,固定螺栓被移除,過濾器元件被移除。更換新的過濾元件并擰緊固定螺栓。檢查是否收緊。打開進出閥,關閉旁通閥并正常使用。
6. When replacing the filter elements, please connect the bypass valve and close the inlet and outlet valve. The compressed air in the emptying slot is removed, the fixing bolt is removed, and the filter element is removed. Replace the new filter element and tighten the fixing bolt. Check for tightening. Open the inlet and outlet valves, close the bypass valves and use them normally.
The small edition of biogas purification will be introduced to you first. Welcome to our official website: http://www.mimi5.cn, to express your different opinions. Thank you for your support.